CE approved 12 channel digital portable cheap ecg machine ECG 1200G

5 Units
MOQ
$880.01(5 - 9 Units) $840.01(>=10 Units)
τιμή
CE approved 12 channel digital portable cheap ecg machine ECG 1200G
Χαρακτηριστικά Εκθεσιακός χώρος Περιγραφή προϊόντων Ζητήστε ένα απόσπασμα
Χαρακτηριστικά
Προδιαγραφές
Model Number: ECG 1200G
Type: Pathological Analysis Equipments
Display: 8"TFT Color LCD
Dimension: 334* 320* 85(mm)
Certificate: CE
Screen: Touch screen
Pixel: 800*600 pixels
Battery supply: lithium ion battery
Lead mode: Standard 12 lead
Net weight: 3.5 kg
Memory: Flash memory
language options: Chinese,English,Turkish,etc
Βασικές πληροφορίες
Πιστοποίηση: CE
Model Number: ECG 1200G
Πληρωμής & Αποστολής Όροι
Περιγραφή προϊόντων

Feature

-12 Lead ECG simultaneous acquisition,simultaneous display of3/6/12lead ECG waveform

-Build-in real-time ananlysis software,average QRS template, RS232 and USB interface

-Multiform printing modes and format:Auto/Manual,standard 12 Ch,3Ch+3R,6Ch,6Ch+1R and 60s arrhythmia report.

-Physical exemination mode (A4 Paper),R-R historgram,trend,average QRS template

-Build-in SD Card

Environment conditions

Environment temperature+5°C~+35°C
Relative humidity≤80%
Power supplyAC:100V~240V,50/60Hz DC:14.8V, 3700 mAh rechargeable lithium battery
Atmospheric pressure86kPa~106kPa
Environment temperature-10°C~55°C
Relative humidity≤95%
Atmospheric pressure50kPa~106kPa

Specifications:

Input way Floating and defibrilation protection
LeadStandard 12 leads
Input impedance ≥50MΩ
Frequenvy response 0.05Hz~150Hz(-3dB,+0.4dB)
Time constant >3.2s
CMRR >60dB, >100dB( Adding filter)
EMG interference filter 35Hz(-3dB)
Fuse specification 2 pcs φ5*20mm AC time lag; T1.6A/250V(Power supply 220V)
Enduring polarization voltage ±300mV
Measurement parameters HR, P-R interval, P Duration, QRS Duration, T Duration, Q-T interval, Q-Tc, P A*is, QRS A*is, T A*is, R(V5) , S(V1) , R(V5)+S(V1)
Rhythm record record setup according to rhythm record format and mode, automatically measuring and analysing
Manual record record setup according to manual record format, manually changing leads
Auto record Record setup according to auto record format and mode, automatically changing leads, measuring and analysing
Noise leavel ≤13μVp-p
Filter AC filter,ECG interference filter,DFT filter
-Sensitivity:Auto 10,20mm/mV±2% ect
Measure date HR,interval,Duration,Axis
Paper speed 25,50mm/s,±%3 ect
Recording paper 210/216mm(W)x20/30m(L)
Safety Type Class I,Typbu xinge CF
Size 338mm(L)x280MM(w)85MM(h)
Net Weight 3.5Kg


Option:

-ECG Worksation Software
-SD Card
-Portable Pack
-Trolley
-7"LCD B/W,Color,Touc
h

YOUR SATISFACTION IS OUR PURSUIT.♥

Συνιστώμενα προϊόντα
Ελάτε σε επαφή μαζί μας
Υπεύθυνος Επικοινωνίας : Andy Shih
Χαρακτήρες Λοιπά(20/3000)